philippine gas-fired vertical boiler draft hood

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • Gas-Fired Boilers

    The boiler in Figure 1 uses the older technology of a draft hood, which pulls dilution air into the vent pipe. The newer boiler in Figure 2 replaces the draft hood with a small induced-draft fan that pulls the products of combustion through the combustion …

    Get Price
  • 1&( & GAS-FIRED Models STEAM BOILERS

    2017-5-4 · Figure 3 - Draft Hood Installation 1. Slide draft hood over flue collector. 2. Through holes in jacket top, secure with 1 or 2 screws, based on boiler size. Draft Hood Screw View from top of boiler Top and side panels not shown for clarity. P/N 240009937, Rev. D 04/30/2017

    Get Price
  • Inspecting Gas-Fired Boilers - InterNACHI®

    2020-1-31 · In a Category I gas-fired natural-draft boiler, the natural draft of the heated flue pulls combustion air through the draft hood and into the combustion chamber (image courtesy of Calcs Plus). Figure 3. A Category I induced-draft boiler uses an induced-draft fan to pull air through the combustion chamber and into the flue (image courtesy of ...

    Get Price
  • CGi Gas Boiler Series 4 - -Residential Boilers

    2021-9-3 · Gas fired water boiler with cast iron sections Natural draft and direct exhaust capability Can be used with natural or propane gas Now with built-in low water cut off functionality Compact design saves valuable living space No vertical draft hood and no mechanical vent damper Intermittent electronic ignition with standard components for easy servicing 84% AFUE

    Get Price
  • GMGW-K Series Gas-Fired Water Boiler

    Pull out burner drawer and removable burner tube tray allow for easy cleaning and quick access to change orifices; LP gas, high altitude. Easy to Install Draft Diverter Includes a low profile draft diverter hood reducing installation height by up to 30' when compared to models with external hoods. Warranty 20 Year Limited Warranty (Residential)

    Get Price
  • CANADIAN ENERGY VERIFIE GAS-FIRED CAST-IRON

    2021-1-19 · DRAFT HOOD The draft hood supplied with SE models is part of the listed boiler assembly. DO NOT alter the hood. See dimensions, page 2. Attach the hood to the boiler flue outlet. Connect flue pipe full size of hood outlet. Vent damper must be installed on the out-let side of the hood. See Vent Piping, below. VENT PIPING

    Get Price
  • UH16 Series Gas Fired Steam Boilers

    2017-5-5 · Install boiler so automatic gas ignition system components are protected from water (dripping, spraying, rain, etc.) during appliance operation and service. Draft Hood Installation WARNING Asphyxiation, carbon monoxide hazard. Failure to follow these instructions could result in improper combustion and possible leakage of combustion

    Get Price
  • PARKERETTE VERTICAL DRUM STEAM BOILER SPEC.

    2015-5-18 · PARKERETTE VERTICAL DRUM STEAM BOILER SPEC. SHEET D-102-I 1-1/2 TO 3 H.P. - ATMOSPHERIC GAS FIRED 7D MODEL NO. 102-1½ 102-3 NO. HORSEPOWER 1½ HP 3 HP A BTU Input 1000's BTU/HR. 65 129 B BTU Output at rating from and at 2120F 1000's BTU/HR. 52 104 C Heating Surface SQ. FT. 16 19.9 ... 4A Vent Stack Diameter with Draft Hood - (Standard) IN. 5 6

    Get Price
  • Peerless MI MIH II Boiler Manual - inspectapedia.com

    2019-1-4 · Boilers Series Gas Installation, Operation & Maintenance Manual. ... 3. 6″ (152 mm) between draft hood and combustible construction. 4. 6″ (152 mm) between vent pipe and combustible ... of the total input rating of all gas fired equipment but not less than 100 in 2(645 cm). One

    Get Price
  • In Line Draft Inducer Vertical Vent Systems for All Fuels ...

    2014-4-14 · Barometric Draft Controls Models: DC4, DC5, DC6, DC7, DC8, DC9, DC10 DC4G, DC6G, DC7G, DC8G, DC9G, DC10G Quality engineered and manufactured to maintain a consistent draft on a wide range of oil and gas fired heating equipment. May be used with chimney vented or power vented heating equipment.

    Get Price
  • CGi Gas Boiler Series 4 - -Residential Boilers

    2021-9-3 · Gas fired water boiler with cast iron sections Natural draft and direct exhaust capability Can be used with natural or propane gas Now with built-in low water cut off functionality Compact design saves valuable living space No vertical draft hood and no mechanical vent damper Intermittent electronic ignition with standard components for easy servicing 84% AFUE

    Get Price
  • Weil McLain - CGi Gas Boiler Series 3 - Boiler Direct

    Gas fired water boiler with cast iron sections. Natural draft and direct exhaust capability. Can be used with natural or propane gas. All units are factory-tested. Compact design saves valuable living space. No vertical draft hood and no mechanical vent damper. Intermittent electronic ignition with standard components for easy servicing.

    Get Price
  • In Line Draft Inducer Vertical Vent Systems for All Fuels ...

    2014-4-14 · Barometric Draft Controls Models: DC4, DC5, DC6, DC7, DC8, DC9, DC10 DC4G, DC6G, DC7G, DC8G, DC9G, DC10G Quality engineered and manufactured to maintain a consistent draft on a wide range of oil and gas fired heating equipment. May be used with chimney vented or power vented heating equipment.

    Get Price
  • UH16 Series Gas Fired Steam Boilers

    2017-5-5 · Install boiler so automatic gas ignition system components are protected from water (dripping, spraying, rain, etc.) during appliance operation and service. Draft Hood Installation WARNING Asphyxiation, carbon monoxide hazard. Failure to follow these instructions could result in improper combustion and possible leakage of combustion

    Get Price
  • Boilers - A.B. Young CompanyA.B. Young Company

    A.B. Young has provided complete boiler system solutions for over 65 years. With years of combined system experience, our product specialists use their applications knowledge and technical skills to understand your project requirements and help you select the best product solutions for your application. Steam Boilers Product info Bryan is a leading manufacturer of quality […]

    Get Price
  • PARKERETTE VERTICAL DRUM STEAM BOILER SPEC.

    2015-5-18 · PARKERETTE VERTICAL DRUM STEAM BOILER SPEC. SHEET D-102-I 1-1/2 TO 3 H.P. - ATMOSPHERIC GAS FIRED 7D MODEL NO. 102-1½ 102-3 NO. HORSEPOWER 1½ HP 3 HP A BTU Input 1000's BTU/HR. 65 129 B BTU Output at rating from and at 2120F 1000's BTU/HR. 52 104 C Heating Surface SQ. FT. 16 19.9 ... 4A Vent Stack Diameter with Draft Hood - (Standard) IN. 5 6

    Get Price
  • DXL Series

    2 days ago · DXL Series. Dunkirk's DXL Series of gas-fired hot-water boilers have an advanced Fuel Smart Hydrostat Control and offers up to 83.5% AFUE. Energy saving features include the electronic ignition system and motorized vent damper to reduce your heating costs. Features a dependable cast iron heat exchanger with cast iron push nipple connections.

    Get Price
  • Fired Heaters - Thermaxglobal

    Fired Heater & Process Furnaces. In the oil and gas segment, fired heaters are essential for heating - thermic fluids, process fluids, feedstock, charge heating, steam heating and thermal cracking in the refinery segment. The design of these units depends on the application and the choice between 'vertical cylindrical' or 'box-type furnace ...

    Get Price
  • Series GM

    2021-5-3 · Draft Hood: 6' (152 mm) 4. Vent Pipe: 6' (152 mm )[1' (25 mm) for Type B vent] ... Mechanical Engineers Safety Code for Controls and Safety Devices for Automatically Fired Boilers, ASME CSD-1. NOTICE ... of the total input rating of all gas fired equipment but …

    Get Price
  • Steam Boiler Questions and Answers

    2021-6-13 · The condenser is a vertical condenser with process vapours on tube side and boiler feed water on shell side. The outlet of the shell side is a two phase flow. ... Also there have to be a burner hood to be constructed all over the burner roof, equally vented. ... I have two 82,000 lb/hr natural gas fired boiler that is designed for 300 psig and ...

    Get Price
  • UH16 Series Gas Fired Steam Boilers

    2017-5-5 · Install boiler so automatic gas ignition system components are protected from water (dripping, spraying, rain, etc.) during appliance operation and service. Draft Hood Installation WARNING Asphyxiation, carbon monoxide hazard. Failure to follow these instructions could result in improper combustion and possible leakage of combustion

    Get Price
  • PARKERETTE VERTICAL DRUM STEAM BOILER SPEC.

    2015-5-18 · PARKERETTE VERTICAL DRUM STEAM BOILER SPEC. SHEET D-102-I 1-1/2 TO 3 H.P. - ATMOSPHERIC GAS FIRED 7D MODEL NO. 102-1½ 102-3 NO. HORSEPOWER 1½ HP 3 HP A BTU Input 1000's BTU/HR. 65 129 B BTU Output at rating from and at 2120F 1000's BTU/HR. 52 104 C Heating Surface SQ. FT. 16 19.9 ... 4A Vent Stack Diameter with Draft Hood - (Standard) IN. 5 6

    Get Price
  • CGA-8 - 172,000 BTU Output Boiler, Spark Ignition w/o ...

    Weil-McLain 381-359-082 - CGA-8 - 172,000 BTU Output Boiler, Spark Ignition w/o Draft Hood - Series 3 (Nat Gas) - Note: Product Title reflects this boiler's IBR Net Output Rating CGa Gas Boiler Series 3 Natural draft, silent operation Compact design saves valuable living space Now with built-in low water cut off functionality Stainless steel ...

    Get Price
  • Series GM

    2021-5-3 · Draft Hood: 6' (152 mm) 4. Vent Pipe: 6' (152 mm )[1' (25 mm) for Type B vent] ... Mechanical Engineers Safety Code for Controls and Safety Devices for Automatically Fired Boilers, ASME CSD-1. NOTICE ... of the total input rating of all gas fired equipment but …

    Get Price
  • Boilers - A.B. Young CompanyA.B. Young Company

    A.B. Young has provided complete boiler system solutions for over 65 years. With years of combined system experience, our product specialists use their applications knowledge and technical skills to understand your project requirements and help you select the best product solutions for your application. Steam Boilers Product info Bryan is a leading manufacturer of quality […]

    Get Price
  • FIELD CONTROLS, LLC - CONTRACTOR PRODUCTS

    2014-4-9 · Gas A double-acting control for gas-fired furnaces and boilers is widely used for conversion burner installations, gas draft-induced appliance operation with mechanical draft inducers or sidewall power venters. It is also recom-mended for use on gas atmospheric appliances where a draft hood cannot be

    Get Price
  • Ager Tank - Brewery Industry Equipment - Boilers - Search ...

    Item is a new stock Weil McLain EGH 105 gas fired low pressure steam boiler. Key Features- -Medium capacity cast iron commercial gas boiler -Combination Gas Valve and Regulator -Non-Linting Pilot Burner -Factory Assembled Section Block -Horizontal to Vertical Draft Hood -Aluminized Steel Burners -Insulated extended steel jacket Unit is sized to work well with our 10 bbl steam heated skid ...

    Get Price
  • Steam Boiler Questions and Answers

    2021-6-13 · The condenser is a vertical condenser with process vapours on tube side and boiler feed water on shell side. The outlet of the shell side is a two phase flow. ... Also there have to be a burner hood to be constructed all over the burner roof, equally vented. ... I have two 82,000 lb/hr natural gas fired boiler that is designed for 300 psig and ...

    Get Price
  • draft hood - Everything2.com

    2001-12-21 · A draft hood is a device used to insure the maintenance of constant low draft conditions in the combustion chamber. By this action, it contributes to the stability of the air supply for the combustion process. A draft hood will also prevent excessive chimney draft and downdrafts that tend to extinguish the gas burner flame.Because of this last function, a draft hood is often referred to as a ...

    Get Price
  • BOILER (BABCOCK & WILCOX BOILER

    2017-2-22 · Both gas and oil fired boilers use controlled combustion of the fuel to heat water. The key boiler components involved in this process are the burner, combustion chamber, heat exchanger, and controls. The burner mixes the fuel and oxygen together and, with the assistance of an ignition device, provides a platform for combustion.

    Get Price
  • GWA Gas-Fired Water Boiler - Union Steam

    2018-3-20 · GWA Gas-Fired Water Boiler 52,000 to 245,000 Btuh Input Natural or Propane . Construction • Atmospheric (chimney) venting ... • Vertical draft hood • Electrical junction box • 24-VAC combination gas valve • Combination relay receptacle and 40VA • …

    Get Price
  • Inspecting Gas-Fired Boilers - InterNACHI®

    2020-1-31 · In a Category I gas-fired natural-draft boiler, the natural draft of the heated flue pulls combustion air through the draft hood and into the combustion chamber (image courtesy of Calcs Plus). Figure 3. A Category I induced-draft boiler uses an induced-draft fan to pull air through the combustion chamber and into the flue (image courtesy of ...

    Get Price
  • Weil-McLain CGI Gas Boiler

    Gas fired water boiler with cast iron sections; Direct vent capability; Can be used with natural or propane gas; All units are factory-tested, and include a limited lifetime warranty on cast iron sections; Compact design saves valuable living space; No vertical draft hood …

    Get Price
  • draft hood - Everything2.com

    2001-12-21 · A draft hood is a device used to insure the maintenance of constant low draft conditions in the combustion chamber. By this action, it contributes to the stability of the air supply for the combustion process. A draft hood will also prevent excessive chimney draft and downdrafts that tend to extinguish the gas burner flame.Because of this last function, a draft hood is often …

    Get Price
  • FIELD CONTROLS, LLC - CONTRACTOR PRODUCTS DRAFT

    2014-4-9 · Gas A double-acting control for gas-fired furnaces and boilers is widely used for conversion burner installations, gas draft-induced appliance operation with mechanical draft inducers or sidewall power venters. It is also recom-mended for use on gas atmospheric appliances where a draft hood cannot be

    Get Price
  • GOLD CGs - OwnerIQ

    GOLD CGs Gas-Fired Water Boiler 4 Part Number 550-141-873/0502 2. Determine venting method Direct exhaust venting Use only when openings for inside combustion air can be supplied in accordance with the CGs Boiler manual, this venting supplement and with all applicable codes. You must direct vent the boiler if the boiler area may

    Get Price
  • BOILER (BABCOCK & WILCOX BOILER

    2017-2-22 · Both gas and oil fired boilers use controlled combustion of the fuel to heat water. The key boiler components involved in this process are the burner, combustion chamber, heat exchanger, and controls. The burner mixes the fuel and oxygen together and, with the assistance of an ignition device, provides a platform for combustion.

    Get Price
  • CGa™-8 Gold Series 2 Commercial and Residential Gas Boiler ...

    Gas fired water boiler with cast iron sections; Easily accessible controls, vertical flueways and top; Does not include Taco 007 circulator or draft hood; LP Model; DOE Heating Capacity: 204 MBH; Net Rating: 177 MBH; Net I=B=R Capacity: 177000 BTU

    Get Price
  • MFC Series Boiler Vent and Combustion Air Guide

    2019-1-25 · The AERCO MFC gas-fired or fuel oil-fired (backup) boiler is a high efficiency, forced draft, hydronic-heating unit with unique venting capabilities. All MFC venting options (which include horizontal and vertical discharges, direct vent, and manifolded vent breeching), typically exceed the capabilities of competing combustion equipment.

    Get Price
  • Boiler-Venting Considerations - Heating Help

    2015-8-13 · Typical efficiency range 78% - 83%. Category IV Appliance operates with a positive vent static pressure at temperatures at or below condensing temperatures. Typical efficiency range is over 90%. Confirm the size of the flue that the old boilers were using. If the old boiler had a draft hood, the flue may be oversized when using a power burner.

    Get Price
  • Type B Vent H&C Draft 151215 - Hart & Cooley

    2016-6-30 · Standard 441 for use with listed gas-fired appliances that have been certified for use with Type B gas vent. B-Vent is intended for neutral or negative draft applications. It is designed for vertical installations (including laterals) but may be used for horizontal applications with a draft-inducing fan located such

    Get Price
  • Weil-McLain CGI Gas Boiler

    Gas fired water boiler with cast iron sections; Direct vent capability; Can be used with natural or propane gas; All units are factory-tested, and include a limited lifetime warranty on cast iron sections; Compact design saves valuable living space; No vertical draft hood …

    Get Price
  • Annual Low Pressure Boiler Inspection Review List

    2021-7-29 · Oil fired systems must have cleanouts located every 15'. Gas fired vent systems must have a cleanout for inspection where the breechings changes by 45 degrees or more in the vertical direction. Barometric damper shall be free swinging and installed to meet the manufacturer's requirements. Draft hoods shall be open and clear. FGC 503.12.3

    Get Price
  • Utica Heating SW Series

    2021-9-1 · The Utica Heating SW Series Gas-Fired Water Boiler features a Honeywell High Limit/Electronic Ignition Control: Recessed under the boiler's protective jacket Digital temperature display and diagnostics Plug in connection for the inducer fan Plug in connection for the system pump Control monitors the water temperature and delays the burner starting until residual heat …

    Get Price
  • FIELD CONTROLS, LLC - CONTRACTOR PRODUCTS DRAFT

    2014-4-9 · Gas A double-acting control for gas-fired furnaces and boilers is widely used for conversion burner installations, gas draft-induced appliance operation with mechanical draft inducers or sidewall power venters. It is also recom-mended for use on gas atmospheric appliances where a draft hood cannot be

    Get Price
  • Mini-Gas Boiler

    Allied Engineering is extremely proud of its compact Mini-Gas series which is ideal for today's energy efficient home, condominium or townhouse.Mini-Gas Hydronic Heating Boilers are manufactured to the highest standards for performance, efficiency, and reliability MINI-GAS Series boilers are available in five compact sizes: 50,000, 75,000, 100,000, 125,000 and 150,000 …

    Get Price
  • Series MI85 - PB Heat: Peerless® Boilers

    2017-12-15 · 3. 6″ (152 mm) between draft hood and combustible construction. 4. 6″ (152 mm) between vent pipe and combustible ... Mechanical Engineers Safety Code for Controls and Safety Devices for Automatically Fired Boilers, ASME CSD-1. NOTICE Do not install this boiler on carpeting. ... of the total input rating of all gas fired equipment but not ...

    Get Price
  • Fundamentals of Venting and Ventilation

    2007-1-15 · FLUE GAS SPILLING OUT OF DRAFT HOOD (1) NO DILUTION AIR – HIGH STACK TEMPERATURES (2) RE-CIRCULATION OF FLUE-GAS INTO COMBUSTION AIR SUPPLY – INCOMPLETE COMBUSTION (3) POSSIBLE FORMATION OF CARBON MONOXIDE AND CORROSIVE COMPOUNDS (4) 4 Resistance to Flow Resistance in a vent pipe can come in several forms. Some

    Get Price
  • Commercial Cooking Hood System - UL

    2020-10-22 · Gas Fired – Wood Fired – Gas-Wood Fired – Sanitation – (KNGT, KNNS) NSF 4 (TSQT), NSF 2 (TSQU) ANSI Z83.11 & UL2162, (LGRC) UL 2162 (LCJX) ANSI Z83.11/CSA 1.8 (LGQX) Shatter Containment UL 2007A (TSXX) Exhaust Hood UL 710 Luminaires and Fittings UL 1598, 2108 (HYXT) (YXZR) or (YYCW) Grease Duct Enclosures UL 2221 or ASTM E 2336 ...

    Get Price
  • draft hood - Everything2.com

    2001-12-21 · A draft hood is a device used to insure the maintenance of constant low draft conditions in the combustion chamber. By this action, it contributes to the stability of the air supply for the combustion process. A draft hood will also prevent excessive chimney draft and downdrafts that tend to extinguish the gas burner flame.Because of this last function, a draft hood is often …

    Get Price
  • Venting of gas appliances in the UMC

    2020-2-28 · Gas-fired appliances are commonly used for space heating, water heating, cooking and more. Such appliances provide comfort and convenience that improve the quality of life. While it is easy to appreciate the benefits of gas appliances, venting of such appliances can, at times, be an afterthought. However, proper ventilation of gas appliances is essential for safety and efficiency, and a ...

    Get Price
  • draft hood - Everything2.com

    2001-12-21 · A draft hood is a device used to insure the maintenance of constant low draft conditions in the combustion chamber. By this action, it contributes to the stability of the air supply for the combustion process. A draft hood will also prevent excessive chimney draft and downdrafts that tend to extinguish the gas burner flame.Because of this last function, a draft hood is often referred to as a ...

    Get Price
  • Back to Basics: Venting for Gas-Fired Boilers

    2003-6-4 · All gas-fired, low pressure steam and hot water boilers certified to the ANSI Z21.13 standard are required to have the vent system category (I, II, III or IV) on the rating plate. The ANSI Z21.13 standard contains a uniform test procedure used to evaluate the vent system of all certified boilers. Vent category specifies whether the vent system ...

    Get Price
  • LexusII Gas-fired Boilers feature: WAYNE COMBUSTION ...

    2007-11-28 · Specifications GWA & GSA GAS-FIRED BOILERS LexusII Gas-fired Water Boiler Boiler 0-2,000 ft. altitude 2,000-4,500 ft. Net Boiler DOE seasonal Chimney Circulator model Input Output altitude (Canada)2 I=B=R water efficiency breeching flange size number Input Output ratings content % A.F.U.E.1 size Btuh Btuh1 Btuh Btuh Btuh2 Gallons N-S L-S N-I x20' high

    Get Price
  • 2006 HHM FINAL - CDC

    2019-2-6 · Damper—A valve for regulating draft on coal-fired equipment. Generally located on the exhaust side of the combustion chamber, usually in the chimney connector. Dampers are not allowed on oil- and gas-fired equipment. Draft hood—-A device placed in and made a part of the vent connector (chimney connector or smoke pipe) from an

    Get Price
  • The G124X Series gas boiler set new standards for quality ...

    2001-5-16 · 1. Draft hood with integral diverter for dilution of flue gases. 2. Boiler sections: flexible cast iron with contoured fins. 3. Deluxe blue enameled insulated boiler jacket. 4. Stainless steel premix burners with high reliability. 5. Gas valve with intermittent ignition or standing pilot. HS2102 Ecomatic Control G124X Series Boiler A.G.A ...

    Get Price
  • 69-1088B - D896 Automatic Vent Damper - Honeywell

    2013-11-8 · Underwriters Laboratories Inc. listed and American Gas Association design certified atmospheric type, gas-fired furnaces and boilers. The furnaces or boilers must be equipped with a draft hood that has an outlet area no larger than the inlet area of the damper. Do not use with an oil-fired furnace or boiler, power burner, or direct vent furnace ...

    Get Price
  • INSTALLATION, OPERATING AND SERVICE

    2015-10-14 · The FORCESTM series boilers are low pressure cast iron gas fired steam boilers designed for use in closed steam ... 15' chimney height is from bottom of Draft Hood opening to top of Chimney. (2) Steam boiler's 'steamable water volume': water volume from NWL (normal water level) to low water cutoff level. ... (24 m) from a vertical wall or ...

    Get Price
  • venting exam Flashcards

    draft hood equipped and fan assisted appliances are considered what category. ... when a gas fired appliance and a solid fuel appliance share the same masonry chimney in an industrial installation, how shall the gas appliance be connected to the chimney ... when an offset must be installed in a common vertical vent you must.

    Get Price
  • Rule of Thumb: Combustion air flowrate estimate? -

    2007-1-19 · CH4 + 2 O2 + 8 N2 = CO2 + 2 H20 + 8N2. So for each cubic foot of gas burned you need 2+8=10 cubic feet of air for perfect combustion. If a furnace was designed for 50% excess air, then each cubic foot of gas would need 15 cubic feet of air. The amount of excess air is going to vary with the appliance design.

    Get Price
  • Type B Vent H&C Draft 151215 - Hart & Cooley

    2016-6-30 · Standard 441 for use with listed gas-fired appliances that have been certified for use with Type B gas vent. B-Vent is intended for neutral or negative draft applications. It is designed for vertical installations (including laterals) but may be used for horizontal applications with a draft …

    Get Price
  • Weil-McLain CGI Gas Boiler

    Gas fired water boiler with cast iron sections; Direct vent capability; Can be used with natural or propane gas; All units are factory-tested, and include a limited lifetime warranty on cast iron sections; Compact design saves valuable living space; No vertical draft hood and no mechanical vent damper

    Get Price
  • Annual Low Pressure Boiler Inspection Review List

    2021-7-29 · Oil fired systems must have cleanouts located every 15'. Gas fired vent systems must have a cleanout for inspection where the breechings changes by 45 degrees or more in the vertical direction. Barometric damper shall be free swinging and installed to meet the manufacturer's requirements. Draft hoods shall be open and clear. FGC 503.12.3

    Get Price
  • Utica Heating SW Series

    2021-9-1 · The Utica Heating SW Series Gas-Fired Water Boiler features a Honeywell High Limit/Electronic Ignition Control: Recessed under the boiler's protective jacket Digital temperature display and diagnostics Plug in connection for the inducer fan Plug in connection for the system pump Control monitors the water temperature and delays the burner starting until residual heat has been transferred.

    Get Price
  • FIELD CONTROLS, LLC - CONTRACTOR PRODUCTS

    2014-4-9 · Gas A double-acting control for gas-fired furnaces and boilers is widely used for conversion burner installations, gas draft-induced appliance operation with mechanical draft inducers or sidewall power venters. It is also recom-mended for use on gas atmospheric appliances where a draft hood …

    Get Price
  • Mini-Gas Boiler

    Allied Engineering is extremely proud of its compact Mini-Gas series which is ideal for today's energy efficient home, condominium or townhouse.Mini-Gas Hydronic Heating Boilers are manufactured to the highest standards for performance, efficiency, and reliability MINI-GAS Series boilers are available in five compact sizes: 50,000, 75,000, 100,000, 125,000 and 150,000 BTU/HR input

    Get Price
  • Series MI85 - PB Heat: Peerless® Boilers

    2017-12-15 · 3. 6″ (152 mm) between draft hood and combustible construction. 4. 6″ (152 mm) between vent pipe and combustible ... Mechanical Engineers Safety Code for Controls and Safety Devices for Automatically Fired Boilers, ASME CSD-1. NOTICE Do not install this boiler on carpeting. ... of the total input rating of all gas fired equipment but not ...

    Get Price
  • Fundamentals of Venting and Ventilation

    2007-1-15 · FLUE GAS SPILLING OUT OF DRAFT HOOD (1) NO DILUTION AIR – HIGH STACK TEMPERATURES (2) RE-CIRCULATION OF FLUE-GAS INTO COMBUSTION AIR SUPPLY – INCOMPLETE COMBUSTION (3) POSSIBLE FORMATION OF CARBON MONOXIDE AND CORROSIVE COMPOUNDS (4) 4 Resistance to Flow Resistance in a vent pipe can come in several …

    Get Price
  • Commercial Cooking Hood System - UL

    2020-10-22 · Gas Fired – Wood Fired – Gas-Wood Fired – Sanitation – (KNGT, KNNS) NSF 4 (TSQT), NSF 2 (TSQU) ANSI Z83.11 & UL2162, (LGRC) UL 2162 (LCJX) ANSI Z83.11/CSA 1.8 (LGQX) Shatter Containment UL 2007A (TSXX) Exhaust Hood UL 710 Luminaires and Fittings UL 1598, 2108 (HYXT) (YXZR) or (YYCW) Grease Duct Enclosures UL 2221 or ASTM E 2336 ...

    Get Price
  • draft hood - Everything2.com

    2001-12-21 · A draft hood is a device used to insure the maintenance of constant low draft conditions in the combustion chamber. By this action, it contributes to the stability of the air supply for the combustion process. A draft hood will also prevent excessive chimney draft and downdrafts that tend to extinguish the gas burner flame.Because of this last function, a draft hood is often referred to as a ...

    Get Price
  • HIGH-EFFICIENCY CGaCAST IRON BOILER

    2021-1-29 · Vertical draft hood Automatic vent damper Combination gas valve for 24 volt Wiring harness Non-linting pilot burner Stainless steel burners Electrical junction box Rollout thermal fuse element High-limit temperature control Circulator (when ordered) − Sizes 25–5: Taco 007e − Sizes 6–8: Taco 007

    Get Price
  • Annual Low Pressure Boiler Inspection Review List

    2021-7-29 · Oil fired systems must have cleanouts located every 15'. Gas fired vent systems must have a cleanout for inspection where the breechings changes by 45 degrees or more in the vertical direction. Barometric damper shall be free swinging and installed to meet the manufacturer's requirements. Draft hoods shall be open and clear. FGC 503.12.3

    Get Price
  • Ager Tank - Weil McLain EGH85 Steam Boiler - New Stock

    Item Name: Weil McLain EGH85 Steam Boiler - New Stock Item #: 6338 Model #: EGH85 Condition: New New Stock - Item is a Weil McLain model EGH85 gas fired low pressure steam boiler. Key Features- -Medium capacity cast iron commercial gas boiler -Combination Gas Valve and Regulator -Non-Linting Pilot Burner -Factory Assembled Section Block -Horizontal to Vertical Draft Hood -Aluminized Steel ...

    Get Price
  • Gas-Fired Boilers - Code Compliance Brief

    The intent of this brief is to provide code-related information about gas-fired boilers to help ensure that the measure will be accepted as being in compliance with the code. Providing notes for code officials on how to plan reviews and conduct field inspections can help builders or remodelers design installations and prepare construction documents, and provide jurisdictional officials with ...

    Get Price
  • Professional Technical Help How To Plan Your

    2019-10-29 · furnaces, boilers, and water heaters. DuraFlex AL is an aluminum flexible relining for masonry chimney. Use with natural gas or liquid propane category I, draft hood equipped appliances, and appliances tested and listed to use Type B Gas Vent. Applications include: natural gas fireplaces, gas-fired furnaces, boilers, water heaters, and wall or

    Get Price
  • Boiler/Burner Combustion Air Supply Requirements and ...

    A periodic boiler flue-gas analysis is the best indicator that an adequate supply of combustion air exists. This, and any necessary burner adjustments, should be performed by a trained technician with the proper equipment to measure the amount of excess oxygen and/or carbon dioxide and ppm of carbon monoxide.

    Get Price
  • Volko draft inducers... Draft Inducers for oil and gas ...

    2019-6-13 · Quality engineered and manufactured to maintain a consistent draft on a wide range of oil and gas fired heating equipment. May be used with chimney vented or power vented heating equipment. For fan assisted gas, oil or solid fuel applications with vent …

    Get Price
  • Peerless Boilers SERIES 63 - SupplyHouse.com

    2014-1-10 · Peerless Boilers SERIES 63 Natural or LP Gas Standing Pilot or Spark Ignition Natural Draft (Chimney) Venting † Single Vent Draft Hood Factory Assembled Sections on Knockdown Boilers † Reduces Installation Time Large Water Content † Ideal for Steam and Large Volume Hot Water Applications † 3' Supply and 2¹⁄₂' Return Skim Tapping

    Get Price
  • GWH COMMERCIAL GAS CIRCULATING WATER HEATERS

    2019-2-25 · WATER SUPPLY BOILER shall be approved for indoor or outdoor installation. Multiple venting options shall be available. Vertical venting systems shall be classified Category I, negative draft, non-condensing, to use type 'B' double wall venting materials. Horizontal or direct vent installations require the use of AL29-4C vent materials.

    Get Price
  • Draft Measurement Guide for Chimneys & Flues

    at DRAFT HOOD, GAS HEATER On gas fired equipment. ... This boiler had a poor draft, a history of sooting problems and a too-short chimney that we were in process of replacing when these photos of draft measurement procedure were made. ... Field ships their draft regulators with the weight installed in position for a vertical flue. The ...

    Get Price